Good morning. Iam glad for the oportunity of posting on this forum. Im new to vibration field but very interested in learning.
I am having a problem using the cross chanel phase feuture on my csi 2130. I am using a 4 chanell mux. For some reason i only get input from channel A and nothing from B channel
I understand i must enanle mux to use this adapter but im only see this option on balance program and not from cross channel phase program.
Thank you in advance for your attention
Regards,
Fredy
Vibe-Rater

Avatar / Picture

Sr. Member / Moderator / Supporter
Registered:
Posts: 1,398
Reply with quote  #2 
I have not used the 4Mux for what you are trying to do.  It is traditionally designed for balancing so you can have plane a and plane b, consequetively collecting data..  I would be using a 2 channel 25 pin A + B to do what you are trying to do. mmmmm rgds