Thanks to all that responded! And thanks for your patience before responding with an update. I've learned a lot, much by challenging things I thought I already knew.
To quickly answer Rusty and Pete's latest... I've screwed this up before. Hard to explain, but it was a circumstance in which it seemed obvious where to stiffen with a shear plate. I was wrong there, but it was of minor consequence, other than embarrassment. Being wrong here means extending an outage or possibly forcing the plant down. So the reason I pursued this is that we have one chance not to screw this up. Taking a few extra steps to make sure we don't ride up on a mode that may not be excited by the hammer, or some other mystery, is something I believe warrants the extra care. We also need to estimate a solution if we decide to add weight, and evaluate it against seismic constraints.
We finally got the modal to match the impact test and motion amplification video. It didn't have to do with applying some stiffness value to the sleeve bearing. I'll try to explain what the FEA guy said. It has to do with how much of the pedestal you choose to model... how far down you go to a level you assume to be fixed or unmoving. Initially we modeled it assuming the sole-plate to be fixed (although we knew it was moving at 0.10 ips-p!). But beneath the sole-plate is a 4-inch thick grout filled base, and below that a 4-inch thick concrete pad. The FEA was revised to include the grout filled base... then tweaked by adjusting some value of bonding between the sole-plate and grout until the modal matched our impact test.
Shout out to motion amplification technology. It was our FEA guy staring at the MA video that prompted him to adjust the model to include the grout filled base. Looking carefully he noticed the base moving a little... just a few pixels. But that prompted him to make the change in his model.
Pete... thanks for considering so carefully how sleeve bearing clearances might affect an impact test. Gave me confidence I might be on to something? I've dabbled with negative averaging... haven't been real successful? Your discussion of springs in series and which springs are actually affected by an impact made me almost think I had no business trying to figure this out? More to learn... 😎
Rusty... Your discussion of the differences between energy from a rotating shaft and a hammer made me consider things I had not up till this point. The impact test was a driving point test targeted at the stator housing adjacent to where it bolts to the end bell. And, yes... the sole-plate is voided and needs some attention. This verified by a tap test, and measured vibration of 0.10 its-p at each corner, and 0.20 ips-p at some areas between pedestal risers.
Steve... the discussion you described with your FEA guy sounds like the same discussion I had with our FEA guy. While he was trying to explain, I'm sure he thought I looked like a dog watchin' TV. But the one thing I got out of it was his explanation of how they adjust the sole-plate bonding to make the model match the impact test. In our case, however, he modeled a fully debonded sole-plate and was still 12 Hz above what we saw on the impact test. It wasn't until he included the 4 inch grout base in the model that he could get the FEA to match the impact test.
John... thanks for the citations! I, as well as Pete, would appreciate to see an article about how sleeve bearings affect an impact test.
Thanks to everyone's interest and attention. Learned a lot! 😎
George