George D
So there's elevated horizontal vibration on a two-pole 400 HP motor.  Amplitude had tripled during a quarterly survey from 0.15 ips-p to about 0.45 ips-p.  It's due to a rocking mode structural resonance... validated by an impact test with a clear peak within 1 Hz of running speed, good coherence and a clear phase roll.  Motion amplification further shows the rocking motion originating all the way down to the base of the pedestal, where it attaches to the grouted sole-plate.  Additionally... leaded blankets were strapped to the motor, and an impact test was performed to see the resonant peak drop about 3 Hz, and the motor run to see the vibration amplitude drop significantly.  It is theorized that a portion of the sole plate has delaminated from the grouted sub-structure, reducing stiffness, allowing Fn to decrease and line up with running speed.
 
To understand the condition and come up with a solution the machine was modeled as carefully as possible... including weights, dimensions, attachments, et al.   Once submitted to an FEA, the calculated rocking mode is way off... much higher than that observed in the impact test FRF.
 
So, now, finally to my friggin' question.  I'm trying real hard to brainstorm an explanation.  These are sleeve bearings... probably with 4-6 mils diametral clearance.  I understand that bearing clearances are difficult to model in an FEA.  But is it possible that these clearances may reduce stiffness, and cause Fn observed by an impact test conducted while shutdown to be dramatically lower than what is calculated by an FEA analysis?  The FEA calculated Fn is over 20% higher than that observed via impact test.
 
I realize that the issue will be further complicated once trying to account for oil film stiffness while in service.  But just curious, here, if anybody has insight on how bearing clearances may affect results of an impact test?
 
Thanks in advance,
George
Reply 0 0
electricpete
 But is it possible that these clearances may reduce stiffness, and cause Fn observed by an impact test conducted while shutdown to be dramatically lower than what is calculated by an FEA analysis?
Yes, fwiw it seems very plausible to me that effective bearing stiffness is affected when bumping a horizontal sleeve bearing machine while stationary. Typical textbooks map sleeve bearing stiffness for various conditions, but I haven't see anything while secured.
  • Rolling. While secured, I'd think there is an additional degree of freedom that when the bearing moves horizontally the rotor can roll very slightly during bump (think about the bearing pushing the shaft horizontally to the left at the bottom elevation of the shaft; and the inertia resisting horizontally to the right at the center elevation... then the elevation difference between bottom and center of the shaft creates a moment arm to rotate the shaft). You might initially be inclined to visualize it as the rotor climbing "up" the side of the bearing, but the movement would be so small that it would be rolling along a very small arc at the bottom where it's practically level. In my view that rolling would certainly affect apparent resonant frequency.
  • Sliding. Sliding could be an alternative to rolling, and there might be some mixture of rolling and sliding.
  • Fixed line contact. If the bearing is very dry and the forces are not enough to overcome static friction to cause sliding or rolling, then the bottom of the shaft may remain effectively glued to the bottom of the bottom of the bearing at a single point/line without rocking about that point (rocking would amount to rolling). I think this would be unlikely to me but if it happened I think it would increase effective bearing stiffness.
  • Time since shutdown. Time since ince shutdown might makes a difference in rolling and sliding tendency. (We find the breakaway torque for a horizontal machine is much higher if it has been sitting idle without rotation for a long time than if it was recently run or rotated.).
  • Linear Time Invariant assumption. When we use the term resonant frequency we are envisioniong a linear time invariant system, but rolling and sliding during bump might violate the both the linear part and the time-invariant-stiffness part.
  • All of these factors couild amount to error or non-repeatability in bump test results while secured.
 
I'm sure you've considered this, but of one option to find out the answer to your question (i.e. to eliminate potential bump test error due to bearing offline-to-running differences) is to perform a running bump test if that is practical. Use either negative averaging or comparison to non-running spectrum (or both) to separate distinguish between the vib from the running machine and the vib from the impacting.
 
At this moment, I am actually very interested in the resonant frequency of a particular horizontal sleeve bearing machine at my plant which is suddenly started "misbehaving" ("Stop that... bad pump, very bad!"). I'm somewhat new to hands-on bump testing, so have stumbled a bit trying to figure things out. Might post separately with a few questions about that.
Reply 1 0
John from PA
There is a paper at Influence of Sleeve bearings on Impact Testing that might be of value.  In my modeling days, long ago in another century we would often use values of about 1 x 10^4 #/in to 1 x 10^5 (for motors) and run both values and see the results.  There is another paper at A Better Understanding of Rotor Dynamics and Support Stiffness that seems to suggest 50000 #/in to 100000 #/in.
Reply 1 0
electricpete
There is a paper at Influence of Sleeve bearings on Impact Testing that might be of value.
I'd be interested to see an article with that title. But you didn't link anything with that title. You linked generic considerations for sleeve bearing stiffness but not in the static condition
Reply 0 0
spciesla
George,
 
I talked with one of my colleagues that has a done a lot of modeling in ANSYS and Me'Scope. He indicated for a structural resonance like you are describing (confirmed via the motion amplification & impact test) the stiffness of the fluid-film bearings are not considered. Due to the delamination, it is near impossible to accurately model the stiffness of the grout & soleplate interface. He said that you would look at the two bounding cases, "everything is loose" or "everything is tight". Your measured natural frequency should lie somewhere between those two limiting cases. He said that the accuracy of the modeled natural frequency wasn't as important as the modeled mode-shapes being similar to you modal test.

We know that for springs in series, the equivalent stiffness is 1/Keq = 1/K1 + 1/K2 + .... 1/Kn. When you calculate this you find that the softest spring is the most important, as the equivalent stiffness will be less than the stiffness of that softest spring. If an interface is completely rigid, the stiffness would be infinite-ish, and 1/K would equal 0 for that component (spring). My thought is that the delaminated condition is resulting in the grout/soleplate interface being the softest spring in the series. To me, you've confirmed that its a natural frequency and that you can affect it by adding mass. I understand your predicament, as management wants to know that the proposed solution will fix the problem and not introduce any other problems.
 
I probably didn't tell you anything that you don't know, but maybe you have enough to move forward to plan and implement a repair. I guess one thing that you could ask is what would the stiffness of the grout/soleplace interface need to be to match the measured natural frequency?
 
Steve
Reply 1 0
Rusty Castleman
stiffness of the fluid-film bearings are not considered
 
That was my initial thought. What are you impacting for resonance testing? In this case I would think it would be the lower half of the bearing housing (if exposed) and if not, any solid part of the motor frame that's inline (vertically) with the motor feet, possibly an endbell bolt "lug". If you don't have that I'd impact the motor foot. What you are looking for is the reponse of the pedestal/support system, and the mass of the motor matters but not the stiffness of the motor rotor. I assmume data has been collected at all the locations where the motor pedestal/frame is connected to the soleplate so you know which connection point is weak. The soleplate should be (but rarely is) connected to the foundation in line with (or proximate to) the feet of the machine and the motor if they are connected to the soleplate, or to the location where the pedestal is bolted to the soleplate. You want the forces generated by the machine assembly tied "directly to ground". This is often (usually?) not the case.
 
Quite often the anchor bolts (J-bolts ideally) are properly attached to the rebar in the foundation when the concrete is poured. But when the skid-mounted machine (or just the sole plate) is installed, it sits atop nuts on the J-bolts, and is leveled. Then the upper nut is torqued, a form is built around the elevated soleplate (or skid frame) and epoxy grout is then flowed or pumped in. This makes the stiffness of the entire support system a function of the grout in the lateral direction, and a function of the soleplate or frame stiffness between the "ground" attachment points. A 1" soleplate 10 ft long is not nearly as stiff as you'd assume, especially if it is anchored at the 4 corners only. Same with a skid frame fabricated with beams or C-channels. What should happen is the soleplate should rest on solid metal plate on either side of every foundation anchor bolt. The plate is leveled using minimal shim plates (as thick as possible). This assures the soleplate is bolted down with a solid metal path all the way to the foundation. If the anchor bolts are properly located (one near each machine foot or pedestal attachment point), all the "grout" does is seal everything up and prevent water ingress and corrosion. I expect that's not the case here.
 
IF you have enough access to the baseplate and you can locate the highest vibration one possible quick-fix is to bore a hole through the baseplate (low profile mag base drill) and install a temporary anchor bolt into the foundation.  Doesn't need to be that large (1/2 or 5/8 would be plenty). I'd use a wedge anchor and also clean the hole and inject epoxy as well (Hilti has a system for this). One caveat is to make the hole in the soleplate larger than the anchor bolt so the bolt doesn't actually touch the plate. Then use several Gr. 8 flat washers (no lock washer) and bolt the baseplate down with the new anchor bolt. This should increase the mounting stiffness considerably.  
 
And if it doesn't, just remove the nut and washers and you're back to where you started. But that's how I'd do it.
Reply 1 0
electricpete
What you are looking for is the reponse of the pedestal/support system, and the mass of the motor matters but not the stiffness of the motor rotor [and bearings]
I would respectfully disagree on those particular points if you are intending to dismiss the role of bearings (as I assumed from the context). What we are looking for is the resonant frequency of the composite system. The bearing stiffness which connects the rotor mass to the stator mass would affect that.
 
Let's say it is a rigid rotor. Then we might model the machine as a 2dof
 
ground --- Kstator --- Mstator --- Kbearing----Mrotor
 
Kstator might reflect grout only, or Kstator and Mstator may reflect a more abstract discretization of a distributed-stiffness / distributed-mass stator system. But either way, Kbearing and Mrotor are very clearly tied to bearing and rotor respectively (*), given my rigid rotor assumption.
 
There is a formula to determine the two resonant frequencies for that 2dof model, and Kbearing plays a prominent role in the formula.
 
(*) as I wrote that sentence about Kbearing being tied directly to the physical bearing, I realized that while running there is an attractive radial EM force between rotor and stator (unbalanced magnetic pull) which is sometimes described as a negative stiffness connected in parallel with the bearings. That doesn't change the conclusion that bearing stiffness matters, but it might be another potential source of error in both the non running bump test and (if not accounted for) the FEA model. Possibly another reason to prefer a running bump test.
 
Link about modeling this EM effect as negative spring stiffness here: https://lutpub.lut.fi/bitstream/handle/10024/162542/Heesoo%20Kim%20A4.pdf?sequence=1&isAllowed=y:
For accurate consideration of the eccentricity condition, mixed eccentricity, axial-varying
eccentricity, and the eccentricity caused by motor frame vibration are modeled and
combined. The force model is established based on a semi-analytical concept. The
analytical formula is combined with a newly introduced correction factor obtained from
finite element analysis results, used for the improvement of the accuracy of the model.
The model of the rotor-bearing system, which includes the UMP model, is developed with
two different methods. In the first method, UMP is added as a spring with negative
stiffness to the rotor model, whereas in the second method, UMP is included as an external
force
He introduced the statement talking about eccentricity, but any orbiting of the rotor within the clearance is an eccentricity that would feed back to bearing stiffness (and in turn affect the orbiting...,. presumably lowering bearing stiffness and increasing the orbit size). How important that effect is depends on how big is the movement (it can probably be neglected for smaller orbits because unlike a traditional spring the em force is highly non-linear, it grows more than linearly with distance)
 
 
To be clear, I'm not suggesting offline bump test is wrong as a blanket statement... maybe it's good enough for most purposes. But when we start sharpening our pencils and considering what effects might affect the impact test results and the modeling, both sleeve bearings and em force would be part of that discussion
Reply 0 0
Barry
What is the force that is exciting the Resonate frequency. Rotor imbalance would be my first suspect.
Barry
Reply 0 0
Rusty Castleman
We may be coming at this from different angles, so let me clarify. IMO, the results of the "modeling" or FEA analysis are moot. There is clearly a structural looseness as evidenced by the MA work. Anytime you have a machine that abruptly changes from smooth to high vibration at 1X it is either a change in rotor balance (could be migration of a broken rotor bar, for example) or a change in structural stiffness (loose bearing bolts, loose endbell bolts, loose motor foot bolts or soft foot, or something in the supporting structure loose or broken). I realize that George is concerned that "the calculations" don't match the phyical reality of the situation; I was more concerned with just fixing the problem.
Reply 0 0
electricpete
Yes that makes sense. I can relate to George's environment where sometimes knowing the way forward is not enough, you have to answer questions and provide justifications.... sometimes to the point of absurdity. In fact I myself have been working on a single pump problem originating from a single vibration measurement for more than two weeks, and during that whole time we've done nothing other than talk, explain, analyse, write decision trees, cover contingencies, contact industry peers, etc (finally going in to pull the pump apart today... whew!).

Anyway it was a good thing that I misunderstood your comment because that allowed me to ramble enough to remind myself that electromagnetic forces may play a role in the discussion.
Reply 0 0
George D
Thanks to all that responded!  And thanks for your patience before responding with an update.  I've learned a lot, much by challenging things I thought I already knew.
 
To quickly answer Rusty and Pete's latest... I've screwed this up before.  Hard to explain, but it was a circumstance in which it seemed obvious where to stiffen with a shear plate.  I was wrong there, but it was of minor consequence, other than embarrassment.  Being wrong here means extending an outage or possibly forcing the plant down.  So the reason I pursued this is that we have one chance not to screw this up.  Taking a few extra steps to make sure we don't ride up on a mode that may not be excited by the hammer, or some other mystery, is something I believe warrants the extra care.  We also need to estimate a solution if we decide to add weight, and evaluate it against seismic constraints.
 
We finally got the modal to match the impact test and motion amplification video.  It didn't have to do with applying some stiffness value to the sleeve bearing.  I'll try to explain what the FEA guy said.  It has to do with how much of the pedestal you choose to model... how far down you go to a level you assume to be fixed or unmoving.  Initially we modeled it assuming the sole-plate to be fixed (although we knew it was moving at 0.10 ips-p!).  But beneath the sole-plate is a 4-inch thick grout filled base, and below that a 4-inch thick concrete pad.  The FEA was revised to include the grout filled base... then tweaked by adjusting some value of bonding between the sole-plate and grout until the modal matched our impact test.
 
Shout out to motion amplification technology.  It was our FEA guy staring at the MA video that prompted him to adjust the model to include the grout filled base.  Looking carefully he noticed the base moving a little... just a few pixels.  But that prompted him to make the change in his model.
 
Pete... thanks for considering so carefully how sleeve bearing clearances might affect an impact test.  Gave me confidence I might be on to something?  I've dabbled with negative averaging... haven't been real successful?  Your discussion of springs in series and which springs are actually affected by an impact made me almost think I had no business trying to figure this out?  More to learn... 😎
 
Rusty... Your discussion of the differences between energy from a rotating shaft and a hammer made me consider things I had not up till this point.  The impact test was a driving point test targeted at the stator housing adjacent to where it bolts to the end bell.  And, yes... the sole-plate is voided and needs some attention.  This verified by a tap test, and measured vibration of 0.10 its-p at each corner, and 0.20 ips-p at some areas between pedestal risers.
 
Steve... the discussion you described with your FEA guy sounds like the same discussion I had with our FEA guy.  While he was trying to explain, I'm sure he thought I looked like a dog watchin' TV.  But the one thing I got out of it was his explanation of how they adjust the sole-plate bonding to make the model match the impact test.  In our case, however, he modeled a fully debonded sole-plate and was still 12 Hz above what we saw on the impact test.  It wasn't until he included the 4 inch grout base in the model that he could get the FEA to match the impact test.
 
John... thanks for the citations!  I, as well as Pete, would appreciate to see an article about how sleeve bearings affect an impact test.
 
Thanks to everyone's interest and attention.  Learned a lot! 😎
 
George
Reply 0 0
Ron Brook
George,
You indicate the stiffness change was fairly quickly. I would think delamination of parts of a base structure to happen over a longer span of time, say months or years.
In my experience, it was always sufficient for impact testing to get the rotor up onto the oil film, so grabbing a strap wrench and giving the shaft a few spins so that it is rotating slowly, was fine.
Now for your link to the paper. I think I might be able to help. I've attached a copy to this reply. I think I know the author.......
My guess on the cause of your problem is a wear in the sleeve bearing has caused a rigid body mode to drop down into the running speed range. GE motors were notorious for requiring bearing clearances as well as the space between the bearing insert and the sleeve to be exactly at spec, and not a 0.0005'" less! It was sometimes advisable to create a 0.001" crush between the insert and the cap.
So, I would check the clearances on your bearings very carefully. Use plastigage. To check for 'crush', you place 0.002" shims on each side of the bearing cap mounting face and then look for the plastigage to read 0.001"! That would indicate a crush of 0.001"
But that is after you check the bearing clearance over the shaft journal.
I would love to see your data. I was fortunate to have a tutorial but Dr. James Deel of Zonic Corporation at the Large Motor and Generator Plant in Schenectady, NY one night in the middle of a snow storm. The test subject was a 2000 hp two pole motor at their test bed. We were impacting the end brackets looking for a mode around 2x line frequency. He took my 100mv / G accel and put in on the shelf. Then, we grabbed a 1 Volt/G accel. He then took my 3 lb. PCB modal hammer and changed the tip to be so soft you could squeeze it between your thumb and forefinger and see it deflect! It's the light gray one in their kit. He then grabbed a 10 lb steel plate, drilled a hole in it and bolted it to the back of my modal hammer. Added mass!
So, you can see what he was accomplishing...more mass to the impact, transfer of that energy down low, since 120 Hz is a low frequency in the modal world, and an accelerometer that could See that energy.
I'm very interested in your testing. Please keep us informed.
Regards,
Ron Brook
 
 
PS - I don't know how much I might have modified my original paper in my book, but I know there's a bunch of things in there that should help learning techs and engineers keep from being bitten by what already bit me!
Reply 0 0
Ron Brook
Thanks to all that responded!  And thanks for your patience before responding with an update.  I've learned a lot, much by challenging things I thought I already knew.
 
To quickly answer Rusty and Pete's latest... I've screwed this up before.  Hard to explain, but it was a circumstance in which it seemed obvious where to stiffen with a shear plate.  I was wrong there, but it was of minor consequence, other than embarrassment.  Being wrong here means extending an outage or possibly forcing the plant down.  So the reason I pursued this is that we have one chance not to screw this up.  Taking a few extra steps to make sure we don't ride up on a mode that may not be excited by the hammer, or some other mystery, is something I believe warrants the extra care.  We also need to estimate a solution if we decide to add weight, and evaluate it against seismic constraints.
 
We finally got the modal to match the impact test and motion amplification video.  It didn't have to do with applying some stiffness value to the sleeve bearing.  I'll try to explain what the FEA guy said.  It has to do with how much of the pedestal you choose to model... how far down you go to a level you assume to be fixed or unmoving.  Initially we modeled it assuming the sole-plate to be fixed (although we knew it was moving at 0.10 ips-p!).  But beneath the sole-plate is a 4-inch thick grout filled base, and below that a 4-inch thick concrete pad.  The FEA was revised to include the grout filled base... then tweaked by adjusting some value of bonding between the sole-plate and grout until the modal matched our impact test.
 
Shout out to motion amplification technology.  It was our FEA guy staring at the MA video that prompted him to adjust the model to include the grout filled base.  Looking carefully he noticed the base moving a little... just a few pixels.  But that prompted him to make the change in his model.
 
Pete... thanks for considering so carefully how sleeve bearing clearances might affect an impact test.  Gave me confidence I might be on to something?  I've dabbled with negative averaging... haven't been real successful?  Your discussion of springs in series and which springs are actually affected by an impact made me almost think I had no business trying to figure this out?  More to learn... 😎
 
Rusty... Your discussion of the differences between energy from a rotating shaft and a hammer made me consider things I had not up till this point.  The impact test was a driving point test targeted at the stator housing adjacent to where it bolts to the end bell.  And, yes... the sole-plate is voided and needs some attention.  This verified by a tap test, and measured vibration of 0.10 its-p at each corner, and 0.20 ips-p at some areas between pedestal risers.
 
Steve... the discussion you described with your FEA guy sounds like the same discussion I had with our FEA guy.  While he was trying to explain, I'm sure he thought I looked like a dog watchin' TV.  But the one thing I got out of it was his explanation of how they adjust the sole-plate bonding to make the model match the impact test.  In our case, however, he modeled a fully debonded sole-plate and was still 12 Hz above what we saw on the impact test.  It wasn't until he included the 4 inch grout base in the model that he could get the FEA to match the impact test.
 
John... thanks for the citations!  I, as well as Pete, would appreciate to see an article about how sleeve bearings affect an impact test.
 
Thanks to everyone's interest and attention.  Learned a lot! 😎
 
George
I forgot to mention how critical is was to get the rotor slow rolling, especially when looking for axial resonance in the end brackets.  Otherwise you add the stiffness of the rotor to the end brackets.
just my two cents…have never seen mass loading work to any degree of success.  Mass changes natural frequencies at a linear rate, stiffness changes them at an exponential rate.
Reply 0 0
Ron Brook
Thanks to all that responded!  And thanks for your patience before responding with an update.  I've learned a lot, much by challenging things I thought I already knew.
To quickly answer Rusty and Pete's latest... I've screwed this up before.  Hard to explain, but it was a circumstance in which it seemed obvious where to stiffen with a shear plate.  I was wrong there, but it was of minor consequence, other than embarrassment.  Being wrong here means extending an outage or possibly forcing the plant down.  So the reason I pursued this is that we have one chance not to screw this up.  Taking a few extra steps to make sure we don't ride up on a mode that may not be excited by the hammer, or some other mystery, is something I believe warrants the extra care.  We also need to estimate a solution if we decide to add weight, and evaluate it against seismic constraints.
We finally got the modal to match the impact test and motion amplification video.  It didn't have to do with applying some stiffness value to the sleeve bearing.  I'll try to explain what the FEA guy said.  It has to do with how much of the pedestal you choose to model... how far down you go to a level you assume to be fixed or unmoving.  Initially we modeled it assuming the sole-plate to be fixed (although we knew it was moving at 0.10 ips-p!).  But beneath the sole-plate is a 4-inch thick grout filled base, and below that a 4-inch thick concrete pad.  The FEA was revised to include the grout filled base... then tweaked by adjusting some value of bonding between the sole-plate and grout until the modal matched our impact test.
Shout out to motion amplification technology.  It was our FEA guy staring at the MA video that prompted him to adjust the model to include the grout filled base.  Looking carefully he noticed the base moving a little... just a few pixels.  But that prompted him to make the change in his model.
Pete... thanks for considering so carefully how sleeve bearing clearances might affect an impact test.  Gave me confidence I might be on to something?  I've dabbled with negative averaging... haven't been real successful?  Your discussion of springs in series and which springs are actually affected by an impact made me almost think I had no business trying to figure this out?  More to learn... 😎
Rusty... Your discussion of the differences between energy from a rotating shaft and a hammer made me consider things I had not up till this point.  The impact test was a driving point test targeted at the stator housing adjacent to where it bolts to the end bell.  And, yes... the sole-plate is voided and needs some attention.  This verified by a tap test, and measured vibration of 0.10 its-p at each corner, and 0.20 ips-p at some areas between pedestal risers.
Steve... the discussion you described with your FEA guy sounds like the same discussion I had with our FEA guy.  While he was trying to explain, I'm sure he thought I looked like a dog watchin' TV.  But the one thing I got out of it was his explanation of how they adjust the sole-plate bonding to make the model match the impact test.  In our case, however, he modeled a fully debonded sole-plate and was still 12 Hz above what we saw on the impact test.  It wasn't until he included the 4 inch grout base in the model that he could get the FEA to match the impact test.
John... thanks for the citations!  I, as well as Pete, would appreciate to see an article about how sleeve bearings affect an impact test.
Thanks to everyone's interest and attention.  Learned a lot! 😎
George
One of the most important items in FEA is modeling the boundary conditions.  No connection is ever the Rock of Gibraltar. Sounds like your FEA tutor got that point made!
Reply 0 0
Dave Reynolds
Got any vibration data you can share? Hi resolution if possible, HVA. Any harmonics or just high 1x? Skirting at the base of 1x rpm? From .15 to .45 is a large change! IMO, there is designed in bearing clearance, so shaft is resting on lower half of bearing, if the clearances were .010, the shaft is still resting on lower half of bearing, not sure if bearing clearances would change natural frequency issue or rotor stiffness.
 
Simple test maybe, put a ratchet strap on shaft, put an eye bolt in one of motor endbell bolt locations at bottom of endbell, apply downward pressure with ratchet strap, check if natural frequency changes. IMO, as long as you do not go to the base, you are effectively changing the shaft/rotor/bearing/endbell stiffness, and not the structure stiffness, correct? IMO, the weight you added and the reduction in vibration would indicate a weak base. Any phase data taken at the base of the rocking pedestal?
 
Have used 1" all thread, drilled thru the base into concrete to stiffen bases in the past
 
Have seen cracked shaft, loose rotor laminations, broken rotor bars, wrong size shims used for alignment/soft foot, worn OD of sleeve bearing holder, all create high 1x rpm.
 
Dave
Reply 1 0
Reply