Vibanalyst
After many years doing vibration analysis I am starting with motor current signature analysis. I am reading as much online information as I can get about the subject at the moment. I find it interesting there is not much information about electrical fluting in correlation with MCSA. I almost can't believe that electrical fluting could not be diagnosed using MCSA. So my question would be does anyone have any experience in the field regarding the problem mentioned above?
Reply 0 0
MarkL
You Might want to chat with Mark Gurney at 3phi Reliability he's very Knowledgeable on the subject and has done work on MCA as well. his website is below.
I'm a Vibration analyst, if you see me running away from a machine, try and keep up!
Reply 0 0
Sledder2
You should measure it to see if you have shaft voltage first. I have used a lead pencil before, grind down to the lead/graphite and then tape a light gauge insulated wire so it makes contact with the exposed lead. Attach the other end of that wire to your volt meter. and attach the black lead from the meter to ground. Touch the pencil to a clean rotating shaft and check for voltage. You should not have over 1 volt.
 
I don't think you will see anything with current analysis. It really doesn't affect motor current that I know of. It's one of those things that make us all go, Hmmm....
Reply 0 0
Dave Reynolds
Possible resource for this subject. Electrical discharge is happening at a high frequency, most likely need a digital oscilloscope to see the voltage spikes
Reply 0 0
John from PA
Reply 0 0
electricpete
I'm with sledder, this is not something that would be detected in current signature analysis. i understand there is some research towards seeing traditional bearing defects in current signature analysis, and fluting would likely fall in that same category, but none of that is ready for prime time afaik.
 
as mentioned, shaft voltage monitoring is an option. also skf sells some kind of emi detector which you would hold next to the bearing for detecting micro-arcing from current on bearings.
Reply 0 0
John from PA
Reply 0 0
Vibanalyst
John, that is a very good article, I enjoyed reading it. Thank you all for your contribution.
Reply 0 0
Ron Brook
Possible resource for this subject. Electrical discharge is happening at a high frequency, most likely need a digital oscilloscope to see the voltage spikes
      Dave,
Still not a fan. Isolation of the NDE on all motors larger than a 444 frame and proper grounding of all motors on VFDs is still the way to go. I brought up inductors with Mark Gurney and was surprised to hear he had utilized them, but he put in the caveat that it was only after not having success in getting shaft currents down below acceptable levels through the methods I just mentioned. He added they removed 99% of any remaining current, but again he was not in favor of going to that step without first confirming the first two.  
Regards,
Ron Brook
Reply 0 0
marksl
I'm with sledder, this is not something that would be detected in current signature analysis. i understand there is some research towards seeing traditional bearing defects in current signature analysis, and fluting would likely fall in that same category, but none of that is ready for prime time afaik.
 
as mentioned, shaft voltage monitoring is an option. also skf sells some kind of emi detector which you would hold next to the bearing for detecting micro-arcing from current on bearings.
Are you referring to the SKF Electrical Discharge Detector Pen TKED 1. I would be interested in hearing from those who have used this device. How accurate is it in detecting EDM generated from squirrel caged motors.
Reply 0 0
MarkL
Mark Gurney has had good success with them but he said tracing the mounting points between the motor and the mounting surface and along the power cables to the terminal box works far better than the way skf shows in the training material. (Waving it like Harry Potter across the end bells of the motor)
I'm a Vibration analyst, if you see me running away from a machine, try and keep up!
Reply 0 0
ckyjohn
SKF TKED works as does traditional spectral analysis. Go high in the spectrum to rotor bar pass frequency range (we use the rotor bar collection specification at the motor NDE) and if you have electrical fluting you will see high range peaks with sidebands at inner or outer race defect frequency instead of 2 X FL sidebands as you would normally see with rotor bar issues. With ultrasound it sounds like a freight train, very loud and easy to pick out. Pull the grease plug and purge with new grease and you may also see the telltale black "burnt" grease from electrical discharge... All in all no need for MCA for this one... Secret is grounding brushes and grounding brush maintenance for AC variable or proper commutator phase alignment for and grounding for DC variable.
Reply 1 0
MarkL
SKF TKED works as does traditional spectral analysis. Go high in the spectrum to rotor bar pass frequency range (we use the rotor bar collection specification at the motor NDE) and if you have electrical fluting you will see high range peaks with sidebands at inner or outer race defect frequency instead of 2 X FL sidebands as you would normally see with rotor bar issues. With ultrasound it sounds like a freight train, very loud and easy to pick out. Pull the grease plug and purge with new grease and you may also see the telltale black "burnt" grease from electrical discharge... All in all no need for MCA for this one... Secret is grounding brushes and grounding brush maintenance for AC variable or proper commutator phase alignment for and grounding for DC variable.
Grounding brushes are an ineffective 'band-aid' ferrite hybrid cores on the output cables of the drive and correct earthing at the end bells is a far more effective long-term measure. I used to sell conductive greases and earthing brushes but both are not a final fix.
https://blueferrite.com/applications/industrial/machinery.html
I'm a Vibration analyst, if you see me running away from a machine, try and keep up!
Reply 0 0
MarkL
Can you go into more detail about “correct earthing of the end bells” please?
Hi Todd I'm referencing a previous comment By Ron Brook on the topic.
ronbrookemd.png
I'm a Vibration analyst, if you see me running away from a machine, try and keep up!
Reply 1 0
Reply