I've seen some strange things in 35 yrs of doing what we do. Here are a few.
  1. Customer asked to have a rebuilt fan balanced because it wasn't pushing enough air. The paddle fan wheel had been replaced with a centrifugal wheel, which was mounted backwards, with no inlet cone installed.
  2. Large pump drawing high current. Customer had read "misalignment" could cause this. In spite of assurances to the contrary, they wanted it aligned. Alignment made no difference, because the newly rebuilt motor was running backwards.
  3. Motor shop had tried twice to balance a centrifugal fan in-place. Shaft looked oddly long. Customer said the "spare" shaft was too short, so they had a longer one made. Bump test indicated resonance. The inlet cone was installed on the wrong side of a duct inlet spool piece, leaving an 8" gap, but the longer shaft "corrected" this problem.
  4. Small steam turbine driving a fan through a "speed reducer" (gearbox) had high vibration and noise in the gearbox. The rebuilt gearbox was set up as a speed "increaser" resulting in the bearings being wrong-side up.
  5. Large fan (6-ton wheel) with water-cooled Sleev-Oil bearings. Fan had very high vibration upon startup after an extended down period. Despite obvious high vibration, the control panel showed normal vibration, so the fan was allowed to run all night, unattended. The next morning the fan was still running with water gushing from the outboard bearing - the shaft had eaten through the bearing and about 3" down into the housing.
  6. Large fan installed with no vibration sensors, despite my protests. Shut it down due to a linear increase in 1X vibration over many months with instructions to "inspect fan wheel before running." Fan was started anyway and was found one morning days later running with the housing blown out and only the backplane of the wheel intact. Blades had "peeled off" due to bad welds (cold joints). Two companion fans had the same issue.
  7. On a 3600 rpm overhung fan, the customer had a steel wheel fabricated (welded) as a direct replacement for the original titanium wheel. New wheel arrived unbalanced, with no balance weights at all. They insisted I try and balance it - when started, it shook the bearings loose before it even got up to speed.
  8. Large cooling tower fan with very high vibration after an extended down period. Was assured the weep holes at the end of the "hollow" blades had been checked for debris (usually birds). Found the remains of a full-grown possum (~ 20 lbs) inside one of the blades.
You could make this stuff up, but no one would believe you.  What strange, improbable things have you seen?
Reply 3 0
electricpete
First few are not really bizarre, but made me laugh:
  • Pulled an outdoor WP2 motor for 1x vibration. Found mud daubbers had been building something resembling a bug convention center inside our rotor.
  • Open motor bearings were replaced without bothering to add grease. Abnormal heat and vibration ensued (who would've guessed?!)
  • I spent a long time troubleshooting a mysterious 1800cpm peak on a 2-pole sleeve bearing induction motor. I even had a bizarre theory about half-times electrical frequency, mentioned somewhere in one old article that I found. Shut down to do a bump test, but the 1800cpm peak was still there with the machine secured. Oh yeah... did I mention that we have a massive 1800rpm turbine generator in the same building? (somehow I forgot about that!)
The next one is truly bizarre in my view:
  • 3600rpm 600hp horizontal sleeve bearing motor drives 7100rpm water pump through gearbox.  Investigated a motor overload trip under mysterious circumstances.  Recorded speed trace indicated the motor load increased from normal 75% load to 150% load over the course of a minute and held at 150% load for almost another minute before it tripped on overload (overload trip is certainly expected for this duration of overload). Winding temperature increase corroborated that the motor was overloaded during this period. Water fluid system traces (flow, dp, delta-Temperature) didn't show any fluid system changes in the pump, nor any change in vibration of the pump (although there were high g's in the gearbox).  Pump inspected, no problems. Gearbox inspected, no problems other than a little dirtier than expected and  some metal particles found at the bottom of the sump. All bearings and gearteeth looked fine. Motor was pulled and sent to a motor shop for load-testing... all sat. Breaker was tested/inspected sat, voltage traces were normal during the event. We did not inspect the shaft driven oil pump at the time, because we didn't imagine it could be related to the event. We walked away from the problem with no smoking gun (which is surprising when you think about all the energy required to double the load on a big induction motor for a minute..... surely dissipating that much energy would leave some evidence somewhere?). Two years later when we did inspect the oil pump for other reasons, we found that the two pins in the pin-drive for the shaft-driven oil pump (gear pump) had worn, disengaged and reengaged in a way that would put axial thrust on a rotor of the gear pump. I believe the axial thrust on that tiny gear pump somehow translated into a torque large enough to overload and trip the gynormous motor. Sounds incredible, but we ruled out absolutely everything else.
Reply 1 0
Rusty Castleman
Pete, something similar. Aluminum foil rolling mill had a problem with "chatter" showing up on rolls in the roll turning machine (huge lathe). I couldn't even see it, but they could and said it showed up on the finished foil. Found a tiny vibration at 3600 rpm, but with harmonics of 1X. Lathe sat on a massive concrete base, isolated from the surrounding floor. Traced it back to a 1-1/2 hp lube pump (with loose bearings) sitting 10 ft away, and the only physical connection to the lathe was a flexible rubber hose.  
Reply 2 0
Zeta
  1. Found the remains of a full-grown possum (~ 20 lbs) inside one of the blades.
 
Priceless
Reply 0 0
Shoveldr
Brought in to "balance" a blower. Took some standard data before starting and it's got a resonance issue being excited by looseness. As I'm looking at the machine a millwright comes up and asked if we had to replace the shaft again. They do it so often they now machine down the shaft so they can just slide the bearings on.

Same plant, brought in to balance a fan. I looked at the rotor and there was a big shiny weld going about 300° around the face of blower. Half the blade tips were worn down and shiney. I asked if it had run rough when they started it and was told it smoothed out after it was "worn in".

Asked to look at a tripper car motor, we were onsite for something else, but our parent company and the motor manufacturers parent company were the same. They kept tripping the breaker, so they replaced the breaker. That didn't fix it, so they decided to replace the brake on the motor, but its an integral assembly and they wanted to see if we could get them just the brake. I walked around the tripper car and on the drive shaft I saw a "T" welded to the end of the shaft sticking out of the pillowblock. My first thought was "I bet that is to hold on the inner race", I ran my hand through the grease and pulled out the remains of the rollers. They still thought it was the brake.
Reply 1 0
fburgos
Did I even mention the welded gear coupling that just wouldn't get properly aligned?
Reply 1 0
Sledder2
I have an outer race of a 22234 spherical roller bearing with electrical fluting, it's a lower bend pulley bearing on a 72" belt line. The noise was unbelievable around the plant.
Reply 0 0
John from PA
Along about 1986 I was called to work on a vertical atomizer drive that had a 14000 RPM output speed.  The client said that the impeller kept coming off while in operation and the unit had high vibration.  It was about 200 feet in the air in a machinery space of a smoke stack with one of those “manlift” elevators to take me and 300# of equipment (the original ADRE) to the top.  The initial ride up was just to check for power availability, table for the equipment, etc.  When I got to the top I noticed the atomizer was designed by my former employer.  I in fact had signed off on the design just a few years earlier and knew that the output shaft had a retention nut that would tend to tighten in operation and the machine had “anti-whirl” directional fluid film bearings.  I had the client bump the motor, and indeed it was being run backwards.  The motor was reversed and on rerun the vibration was very low.  I never needed to take my equipment up to the work space.  I also never told the client that I had worked for the atomizer manufacturer.  Probably one of the shortest jobs I ever did.  The client had missed the notation on a drawing that said “CW looking down” (or vice versa).
Reply 0 0
Danny Harvey
I was called to balance a bag house fan that my predecessor in business had balanced about a dozen times over the last few years. I decided that I would go with him to balance it again just to see if he knew what he was doing.
 
He got it all set up and started the fan but I immediately told him to shut it down because it was running backwards. It had been running backwards for 17 years evidently and my guy had never even looked. A couple of hours of loto, rewiring, etc and we started it back up, collected data and went home. No balance required.
 
I was called to balance another fan in a papermill that handled really wet, dirty air. I told them to clean the rotor and they took me seriously. They had 8-5 gallon buckets full of grime and rusty rotor and some very thin fan blades. The buckets weighed at least 70 pound each and it really wasn't a big fan. Then they told me that they couldn't run it! So I spun it around and attached magnets until I found a good static position and put some weight where it worked out best, aligned and tensioned the v-belt drive and told them to give it a try after I was far enough away to not get hit. I was pretty close though. It was about .35 ips at fan speed. It ran ok until the roof it was on collapsed. They had done a real nice job putting a structural steel base on that really rickety roof. I told them at the time that they were putting a really nice treehouse in an old dead tree.
 
I've got too many more to list. I haven't seen everything, but I've sure seen my share of dumb stuff. I may have even done some of it.
Reply 0 0
Danny Harvey
If Rusty was really smart and had an odd number of blades, he could have balanced the possum with two squirrels.
Reply 4 0
Rusty Castleman
The client said that the impeller kept coming off while in operation and the unit had high vibration.
 
Running things backwards seldom ends well. Power plant (800MW) startup. They (I was not involved) were going to run a large vertical river intake pump for the first time, or maybe they were just going to "bump" it for rotation. Whichever, when they hit the button it started (across the line), the impeller spun off the shaft and when it hit the bottom of the pit, it jacked the pump housing and motor off the foundation, breaking the base bolts. BTW, there is (was?) a device called a "phase rotation meter." Not exactly sure how it works, but it's connected to the motor leads, the motor is turned by hand, and it indicates what the rotation will be. That's what we used during startup instead of just "bumping" the motor. That was 35 years ago and I've never seen one since.
Reply 1 0
HuskerTim
Running things backwards seldom ends well. Power plant (800MW) startup. They (I was not involved) were going to run a large vertical river intake pump for the first time, or maybe they were just going to "bump" it for rotation. Whichever, when they hit the button it started (across the line), the impeller spun off the shaft and when it hit the bottom of the pit, it jacked the pump housing and motor off the foundation, breaking the base bolts. BTW, there is (was?) a device called a "phase rotation meter." Not exactly sure how it works, but it's connected to the motor leads, the motor is turned by hand, and it indicates what the rotation will be. That's what we used during startup instead of just "bumping" the motor. That was 35 years ago and I've never seen one since.
Several offline phase rotation meters on the market, just one example linked below.
 
How does it work: most motors will have residual magnetism in the rotor unless they have been offline for a long time OR have a very high quality rotor i.e. extremely uniform fabricated copper rotors. When you rotate the shaft by hand, the meter is sensing the secondary field from this residual and, based on how you have the meter connected to the leads, it will confirm the connections vs the forward hand rotation. The user will have to interpret the results: if the 1-2-3 connection of the meter shows the opposite of the hand rotation, swap 2 leads and retest and note the lead sequence that corresponds the direction of rotation desired.
 
Reply 1 0
tomcd3
Seems that backwards rotation is a common theme here. I’ll keep that in mind more often now. Thx for the suggestion and the laughs.
Reply 0 0
Rusty Castleman
Once a hot-shot fan balancer I know was going to nail the balance of a large baghouse fan at a steel mill with one shot. Using influence coefficients from similar fans, he carefully calculated his trial weight and drew his usual diagram based on the direction of rotation he observed (and marked on the housing) during the coastdown. The fan was opened and he confidently clamped on several pounds of weight (12,000 lb rotor). When the fan started his first thought was "What the hell happened?!?!" Vibration had doubled, from 10 mils to 20 mils (very exciting). When the fan was opened he looked very carefully at the weights, then at the rotor, then at the rotation arrow he'd marked on the housing. It's not helpful when you mark the rotation... backwards.
Reply 0 0
John from PA
Seems that backwards rotation is a common theme here. I’ll keep that in mind more often now. Thx for the suggestion and the laughs.
If I thought I had the potential of balancing a machine with a large motor I carried  a Fluke 9040.  A few minutes with the device and you would know the rotation.  If you bumped the motor you may have lost a start.  Many large motor are limited in number of starts per hour.