Xracer and Willis79,
Sorry for the delay in responding. I have been speaking at a large conference on Vibration and HFE (High Freq. Energy such as Acceleration Enveloping, PeakVue, Amplitude Demodulation, etc.).
It turns out that so many vibration analysts are missing a large portion of major problems, and we have found out why. Many gearboxes, centrifugal and rotary screw compressors, rolling mills, tablet presses, etc., are failing with either little no warning of impending failures – particularly when gear mesh frequencies exceed approximately 9,000 Hz (540,000 CPM), thereby requiring data out to at Least 30,000 Hz (1,800,000 CPM) top pick up a number of gear problems such as tooth wear, misaligned gear teeth, tooth eccentricity, etc.). Such problems require data out to an Fmax of at least 3.25 X GMF, using a High Frequency sensor such as an IMI 621B40 (that can measure within +/- 10% out to 32,000 Hz).
I know this sounds like very high frequency for both vibration and HFE data, but it definitely is required to detect problems such as those outlined above.
In addition, Time Waveform data out to at least 10,000 Hz (600,000 CPM) is required to detect each of the following problems:
Cracked or Broken Teeth; Rolling Element Bearing Defects on Low-Speed Machinery; Lubrication Faults; Special Electrical Problems; and a host of similar problems that can only be detected if Time Waveforms are acquired up to at least 10,000 Hz (otherwise, they will be missed). And we have found that this can add up to missing as much as 20% of all problems on critical machinery - causing PdM vibration programs to lose credibility!
We teach this in our Time Waveform Analysis and Advanced Vibration seminars required for Category IV. Not only do we teach the theory, but also provide a series of real-world case studies we have performed over the last 35 years.
And this recently again caught my attention when one of our major clients again missed two major such problems on production machinery that cost them a little over $1,000,000/day – simply because they did follow guidelines given to them by us on required Fmax – but failed to store the time waveform. That is, they had vibration and HFE Spectra out to the required 10,000 Hz, but such faults did not appear in the spectra whatsoever. These problems were multiple broken gear teeth on the input gear in a gearbox and a severe lubrication fault (each of which can be easily seen and tracked if analysts would store and evaluate their time waveforms and Spectra (but both are required)! No special high frequency accelerometers are required for 10,000 Hz data acquisition.
How did we learn this? By missing most all of the above problems ourselves until we learned that you must take the data out to the minimum Fmax given above. I am now in the middle of writing a paper and preparing a webinar that should be given after the first of 2027, summarizing the theory and giving some of the actual case studies so that these problems can be detected by many vibration analysts and engineers around the world. My reason for revealing this on this excellent forum – to help educate many of you and your colleagues involved with critical machinery reliability programs and processes.
Thank you, fellow “Vibration Nerds”,
Jim Berry, Technical Associates of Charlotte