Rusty Castleman
We want to have content here that is useful to you. So it would be helpful if we knew what analyzers you use. Add any details you would like to about your setup - what you use it for, features or accessories you use, what you do or don't like about it, etc.
Reply 0 0
Rusty Castleman
My late friend Don Rainey was fond of saying, “It doesn’t take long to collect more data than you can explain.”
 
My favorite feature (besides Bluetooth audio output) is having a trend of the last 24 values of every parameter for every point available for display on the meter in the field. I quite often check to see if something I think is getting worse really is or not. Also nice to be able to show a deteriorating trend to a supervisor or manager in the field before I leave the plant. 

But I rarely needed or used 4-channels.
Reply 0 0
Willis79
Recently switched from Commtest to Betavib. Main reason was lack of portable support from BN. Now, I wish we would have switch to Betavib a lot sooner.
Can you provide some of things that you like about the Betavib? Is there anything you miss about Commtest and Ascent?
Reply 0 0
JimWolf
Since we have done so much vibration training and certification since approximately 1985, we have used a wide variety of analyzers and software from a number of vendors. We have carefully built mutually beneficial relationships with such vendors over the last 30 to 35 years. These include CSI/Emerson, SKF, Commtest/Bently Nevada, Entek IRD, Azima, Pruftechnik, Alta Solutions, Hewlett-Packard, Scientific Atlanta, UE Systems, SDT, RDI, etc.
 
Not only have we used these instruments and software in the classroom, but we have also conducted fieldwork at industrial plants, performing a wide range of vibration diagnostics, modal analysis, and condition monitoring over this 35-year period.
 
Jim Berry, Technical Associates of Charlotte
Reply 0 0
Joshua1981
I am currently waiting for some demo units from ADASH to arrive, (VA5 pro and a VA3 pro), I've had the DDS software installed for a couple weeks now and so far am liking what I see. Is anyone using their continous monitoring system in server-based DDS pro and if so, would you share some screenshots and/or thoughts on it?
Reply 0 0
Xracer
Can you provide some of things that you like about the Betavib? Is there anything you miss about Commtest and Ascent?
Sorry. Its been awhile since Ive logged on. Big things Ive noticed is the Betavib is alot faster at data collection. It has a abilty to reprocess the data at anytime which can decrease the time going back out and recollecting the data. Live data is alway dispalyed on the unit eliminating the need to make a recording and then go back to review it. For quick spot checks this is very helpful. Cross phase will generate a report so there is no need to record the amplitude/phase on paper. The 4K analysis feature is awsome. Every thing you need is displayed on one screen.
 
Sample.jpg
Reply 0 0
Zeta
I use VB7 and VB8 its an unfortunate fact that they are obsolete however I cannot find a better alternative.
Reply 0 0
Willis79
I am currently waiting for some demo units from ADASH to arrive, (VA5 pro and a VA3 pro), I've had the DDS software installed for a couple weeks now and so far am liking what I see. Is anyone using their continous monitoring system in server-based DDS pro and if so, would you share some screenshots and/or thoughts on it?
How did your trial with ADASH go? Did you end up purchasing one of those units?
Reply 0 0
İ.GÜRBÜZ
Merhabalar,
1994-2016.......MasterTrend/AMS SUITE/CSI/EMERSON 2110-2120-2130.......Kağıt Makinesi......Beloit/Valmet/Metso
2016-2021........AMS SUITE/EMERSON 2140.......Genel Hizmet
2023'ten itibaren kullanmaya devam ediyoruz SKF @PTITUDE ANALYST 9/SKF Microlog analyzer CMVA DBX 90.......Genel Hizmet.
Reply 0 0
Xracer
I use VB7 and VB8 its an unfortunate fact that they are obsolete however I cannot find a better alternative.
Coming from the same VB7 and VB8 user both Ascent and Sys1, switching to Betavib has worked out great for us. For a single tablet user, all data is stored on the tablet so there is no need to upload to a computer to analyse. We are running two tablets fo where have a network DB setup so both tablets are in sync.
Reply 0 0
Joshua1981
How did your trial with ADASH go? Did you end up purchasing one of those units?
I did not, I liked the boxes and the smaller route collector, but I had 3x 2140s on rental and negotiated a good price to buy them out right and moved over to AMS Machine Works.
Reply 0 0
JimWolf
Xracer and Willis79,
 
Sorry for the delay in responding. I have been speaking at a large conference on Vibration and HFE (High Freq. Energy such as Acceleration Enveloping, PeakVue, Amplitude Demodulation, etc.).
 
It turns out that so many vibration analysts are missing a large portion of major problems, and we have found out why. Many gearboxes, centrifugal and rotary screw compressors, rolling mills, tablet presses, etc., are failing with either little no warning of impending failures – particularly when gear mesh frequencies exceed approximately 9,000 Hz (540,000 CPM), thereby requiring data out to at Least 30,000 Hz (1,800,000 CPM) top pick up a number of gear problems such as tooth wear, misaligned gear teeth, tooth eccentricity, etc.). Such problems require data out to an Fmax of at least 3.25 X GMF, using a High Frequency sensor such as an IMI 621B40 (that can measure within +/- 10% out to 32,000 Hz).
 
I know this sounds like very high frequency for both vibration and HFE data, but it definitely is required to detect problems such as those outlined above.
 
In addition, Time Waveform data out to at least 10,000 Hz (600,000 CPM) is required to detect each of the following problems:
Cracked or Broken Teeth; Rolling Element Bearing Defects on Low-Speed Machinery; Lubrication Faults; Special Electrical Problems; and a host of similar problems that can only be detected if Time Waveforms are acquired up to at least 10,000 Hz (otherwise, they will be missed). And we have found that this can add up to missing as much as 20% of all problems on critical machinery - causing PdM vibration programs to lose credibility!
 
We teach this in our Time Waveform Analysis and Advanced Vibration seminars required for Category IV. Not only do we teach the theory, but also provide a series of real-world case studies we have performed over the last 35 years.
 
And this recently again caught my attention when one of our major clients again missed two major such problems on production machinery that cost them a little over $1,000,000/day – simply because they did follow guidelines given to them by us on required Fmax – but failed to store the time waveform. That is, they had vibration and HFE Spectra out to the required 10,000 Hz, but such faults did not appear in the spectra whatsoever. These problems were multiple broken gear teeth on the input gear in a gearbox and a severe lubrication fault (each of which can be easily seen and tracked if analysts would store and evaluate their time waveforms and Spectra (but both are required)! No special high frequency accelerometers are required for 10,000 Hz data acquisition.
 
How did we learn this? By missing most all of the above problems ourselves until we learned that you must take the data out to the minimum Fmax given above. I am now in the middle of writing a paper and preparing a webinar that should be given after the first of 2027, summarizing the theory and giving some of the actual case studies so that these problems can be detected by many vibration analysts and engineers around the world. My reason for revealing this on this excellent forum – to help educate many of you and your colleagues involved with critical machinery reliability programs and processes.
 
Thank you, fellow “Vibration Nerds”,
Jim Berry, Technical Associates of Charlotte
Reply 2 0
Xracer
Xracer and Willis79,
 
Sorry for the delay in responding. I have been speaking at a large conference on Vibration and HFE (High Freq. Energy such as Acceleration Enveloping, PeakVue, Amplitude Demodulation, etc.).
 
It turns out that so many vibration analysts are missing a large portion of major problems, and we have found out why. Many gearboxes, centrifugal and rotary screw compressors, rolling mills, tablet presses, etc., are failing with either little no warning of impending failures – particularly when gear mesh frequencies exceed approximately 9,000 Hz (540,000 CPM), thereby requiring data out to at Least 30,000 Hz (1,800,000 CPM) top pick up a number of gear problems such as tooth wear, misaligned gear teeth, tooth eccentricity, etc.). Such problems require data out to an Fmax of at least 3.25 X GMF, using a High Frequency sensor such as an IMI 621B40 (that can measure within +/- 10% out to 32,000 Hz).
 
I know this sounds like very high frequency for both vibration and HFE data, but it definitely is required to detect problems such as those outlined above.
 
In addition, Time Waveform data out to at least 10,000 Hz (600,000 CPM) is required to detect each of the following problems:
Cracked or Broken Teeth; Rolling Element Bearing Defects on Low-Speed Machinery; Lubrication Faults; Special Electrical Problems; and a host of similar problems that can only be detected if Time Waveforms are acquired up to at least 10,000 Hz (otherwise, they will be missed). And we have found that this can add up to missing as much as 20% of all problems on critical machinery - causing PdM vibration programs to lose credibility!
 
We teach this in our Time Waveform Analysis and Advanced Vibration seminars required for Category IV. Not only do we teach the theory, but also provide a series of real-world case studies we have performed over the last 35 years.
 
And this recently again caught my attention when one of our major clients again missed two major such problems on production machinery that cost them a little over $1,000,000/day – simply because they did follow guidelines given to them by us on required Fmax – but failed to store the time waveform. That is, they had vibration and HFE Spectra out to the required 10,000 Hz, but such faults did not appear in the spectra whatsoever. These problems were multiple broken gear teeth on the input gear in a gearbox and a severe lubrication fault (each of which can be easily seen and tracked if analysts would store and evaluate their time waveforms and Spectra (but both are required)! No special high frequency accelerometers are required for 10,000 Hz data acquisition.
 
How did we learn this? By missing most all of the above problems ourselves until we learned that you must take the data out to the minimum Fmax given above. I am now in the middle of writing a paper and preparing a webinar that should be given after the first of 2027, summarizing the theory and giving some of the actual case studies so that these problems can be detected by many vibration analysts and engineers around the world. My reason for revealing this on this excellent forum – to help educate many of you and your colleagues involved with critical machinery reliability programs and processes.
 
Thank you, fellow “Vibration Nerds”,
Jim Berry, Technical Associates of Charlotte
Jim,
This is why I have different measurement packs for specific machine configurations. The TWF is always recorded with each pack.
Reply 0 0
JimWolf
Xracer, I am glad you do have measurement pack capability. When doing so, do you take 10,000 Hz Fmax vibration and HFE data for both Spectra and Time Waveforms, at least in one direction, on each rolling element bearing cap? I added the discussion on one of our clients because they took the 10,000 Hz measurements but threw away the TWF! If anyone does this, they just threw away detection of at least eight (8) major problems that can end up in catastrophic failures (a common occurrence all over the world). I believe you use Commtest/Bently instruments that can easily take this data and process it well for both TWF’s and FFT’s.
Thanks, Jim Berry
Reply 0 0
Zeta
Coming from the same VB7 and VB8 user both Ascent and Sys1, switching to Betavib has worked out great for us. For a single tablet user, all data is stored on the tablet so there is no need to upload to a computer to analyse. We are running two tablets fo where have a network DB setup so both tablets are in sync.
How do you find the analysis software compared to Ascent.
My experience with tablet type touch screens had left me feeling that a button option is mandatory.  
Reply 0 0
Zeta
Merhabalar,
1994-2016.......MasterTrend/AMS SUITE/CSI/EMERSON 2110-2120-2130.......Kağıt Makinesi......Beloit/Valmet/Metso
2016-2021........AMS SUITE/EMERSON 2140.......Genel Hizmet
2023'ten itibaren kullanmaya devam ediyoruz SKF @PTITUDE ANALYST 9/SKF Microlog analyzer CMVA DBX 90.......Genel Hizmet.
How do you find the dBX? I like the balance system, although I’ve never figured out how to actually make the finished report with it.
Beyond that I haven't had a single “wow I can do that now!” Moment with it.
Reply 0 0
Reply